ES/MP/DK3-SATIN • Gaboon Satin Finish • Envirograf Fire Door Upgrade Coatings With Veneer

ES/MP/DK3-SATIN • Gaboon Satin Finish • Envirograf Fire Door Upgrade Coatings With Veneer

ES/MP/DK3-SATIN • Gaboon Satin Finish • Envirograf Fire Door Upgrade Coatings With Veneer

GBP179.69

£179.69 Ex VAT [1 item]
£175.20 Ex VAT [2 - 3]
£170.71 Ex VAT [4 +]

Availability : Preorder [Non Returnable] • Manufactured to order within 3 working days • Sold and priced per KIT

    Application : A comprehensive system for upgrading flat panelled doors to fire-rated doors • Intumescent cloth can be applied to existing panelled doors in order to upgrade them to 30 minute fire doors • Intumescent cloth can also be used between 6mm plywood panels if new doors are being made, giving 30 minutes of fire protection
    Fire Test Performance : The intumescent card, ply & veneer have all been fully tested to BS476 Part 22 (1987) on newly-manufactured and old doors at UKAS-approved test centres • Achieved in excess of 30 minutes of fire resistance on softwood doors made from 31mm stiles and rails with 6mm panels • For 60 minutes protection, the thickness of the door should be 44mm minimum • Tested at VNE to European Standard EN 1363-1 (2000).
    Contents :
    White : 900mm x 1350mm Material/Fire Card • 75ml Stabond • 250ml Undercoat • 2 x 310ml tube intumescent adhesive • 500ml Intumescent coating • 500ml Premier top coat
    Pine : 1200mm x 1200mm Pine veneer • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Oak : 1200mm x 1200mm Oak veneer • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Gaboon : 1200mm x 1200mm Gaboon Plywood • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Options : Kits can be coloured to BS or RAL colours for an additional charge
    Note : Please check with your local Building Control Office to ensure that the use of this product will satisfy their individual fire door requirements
    Application : A comprehensive system for upgrading flat panelled doors to fire-rated doors • Intumescent cloth can be applied to existing panelled doors in order to upgrade them to 30 minute fire doors • Intumescent cloth can also be used between 6mm plywood panels if new doors are being made, giving 30 minutes of fire protection
    Fire Test Performance : The intumescent card, ply & veneer have all been fully tested to BS476 Part 22 (1987) on newly-manufactured and old doors at UKAS-approved test centres • Achieved in excess of 30 minutes of fire resistance on softwood doors made from 31mm stiles and rails with 6mm panels • For 60 minutes protection, the thickness of the door should be 44mm minimum • Tested at VNE to European Standard EN 1363-1 (2000).
    Contents :
    White : 900mm x 1350mm Material/Fire Card • 75ml Stabond • 250ml Undercoat • 2 x 310ml tube intumescent adhesive • 500ml Intumescent coating • 500ml Premier top coat
    Pine : 1200mm x 1200mm Pine veneer • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Oak : 1200mm x 1200mm Oak veneer • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Gaboon : 1200mm x 1200mm Gaboon Plywood • 75ml Stabond • 250ml primer • 2 x 310ml tube intumescent adhesive • 333ml Clear intumescent coating • 250ml Premier top coat
    Options : Kits can be coloured to BS or RAL colours for an additional charge
    Note : Please check with your local Building Control Office to ensure that the use of this product will satisfy their individual fire door requirements